Freezing temperatures and water left inside a sewer jetter are a terrible combination. If you’re shutting down your jetter for the winter or expect freezing temperatures before you’ll use it again, winterize it before storage.
Winterizing is not required after every daily shutdown, and it does not prevent you from using the jetter during cold weather, but you’ll need to flush the antifreeze from the system before putting the machine back into service. Here’s how to do it properly.
How to Winterize a Harben Jetter
The following procedure applies only to Harben High-Pressure Water Jetters equipped with an antifreeze system. Some Harben jetters may not include this system, so do not attempt to follow these steps unless your machine is equipped with the required antifreeze tank, valves, and connections. Before starting, confirm your jetter’s configuration and make sure you’re familiar with its controls and valves.
1. Shut off the water supply.
Close the Water Shut-Off Valve located on the inlet line from the water tank.
2. Drain the water tank.
Open the drain valve and allow the tank to drain. Leave the valve open while completing the winterization process.
3. Open the antifreeze supply.
Open the antifreeze tank ball valve.
4. Connect the jetting hose to the recirculation line.
Connect the jetting hose to the recirculation line fitting located below the hose reel.
5. Check the recirculation valve.
Make sure the recirculation ball valve handle is in the vertical position.
6. Turn the jump jet off.
Make sure the jump jet valve is in the OFF position.
7. Close the flow diverter valve.
Turn the flow diverter knob fully clockwise.
8. Start the jetter.
Turn on the jetter and engage the water for about four seconds. This begins drawing antifreeze through the system.
9. Turn the jump jet on.
Move the jump jet valve to the ON position.
10. Watch the jump jet hose.
Watch the clear braided jump jet hose running up the back of the tank. Once you see antifreeze fill the hose, immediately turn the jump jet valve back to OFF. This should take about four seconds.
11. Circulate antifreeze through the recirculation line.
Turn the recirculation ball valve handle to the horizontal position. Watch the second clear braided hose running up the back of the tank. When the fluid in the hose changes to the color of the antifreeze, quickly return the recirculation ball valve to the vertical position.
12. Turn off the jetter.
13. Close the tank drain.
Once all water has drained from the tank, close the drain valve.
14. Protect the suction inlet line.
Leave the antifreeze valve open. Quickly open and close the Water Shut-Off Valve to allow some antifreeze into the suction inlet line.
Your jetter is now protected for storage in freezing conditions.
Want to see the process? Watch Harben’s step-by-step winterizing video for a visual walkthrough of the procedure.
Bringing Your Jetter Back into Service
When freezing conditions are over and you’re ready to use the jetter again, you’ll need to flush the antifreeze from the system first.
- Close the antifreeze valve.
- Close the drain valve.
- Set the two-way ball valve.
Place the handle for the two-way ball valve in the horizontal position. - Open the tank isolation valve.
- Refill the water storage tank with clean water.
- Turn off the jump jet.
Make sure the jump jet valve is in the OFF position. - Start the jetter.
Start the engine at idle with the selector on HIGH-PRESSURE. If the unit uses a radio control, turn the water on as soon as the engine starts. - Monitor the antifreeze mixture.
Watch the antifreeze mixture returning to the tank. As it reaches the top of the tank, turn the engine off. - Turn on the jump jet.
Place the jump jet valve in the ON position. - Return the jetter to service.
The machine can now be operated normally.
Harben recommends regularly checking the strength of the antifreeze mixture to make sure it maintains at least a 50/50 mixture. The winterizing procedure typically takes only a few minutes once you’re familiar with the controls and valves, so taking a machine out of service for freezing conditions does not have to be a major undertaking.
Returning it to service also involves flushing the antifreeze from the system and can usually be completed quickly, but plan enough time to complete the full procedure before starting work.
Do not discharge antifreeze into a sewer or storm drain unless local regulations specifically allow it. Collect and dispose of used antifreeze according to local requirements.
Think Your Jetter May Have Frozen? Do Not Start It!
If a jetter has been exposed to freezing temperatures or a hard frost and you aren’t sure that it was properly winterized, don’t start the pump to find out. Trying to force-start frozen equipment can turn freeze exposure into serious mechanical damage. Move the unit to a warmer location and allow it to thaw completely before attempting to operate it.
There is no reliable external indicator that confirms the entire system has thawed. Check for visible ice around the pump, hoses, valves, and fittings, but remember that water may remain frozen inside components even when the exterior appears clear.
If you suspect freeze damage, contact Harben Support before putting the machine back into service. Again, do not start the machine until it has thawed completely.
Make Winterizing Part of Your Routine
Cold weather doesn’t always give you much warning. A relatively mild day can be followed by an overnight freeze, and that’s enough to put unprotected equipment at risk.
If freezing temperatures are in the forecast, don’t wait until the last minute. Give your crew time to finish the entire procedure and make winterizing part of the normal shutdown routine throughout the cold-weather season.
For additional instructions, consult the Frost Precautions section of your machine’s manual, speak with a Harben representative, or visit Harben Support.